When running dosing system should pay attention to what important matters? When running dosing system, pay attention to the following points: A. dosing pressure B. Stroke frequency C. Suction height D. Altitude E. Corrosive chemicals More: Provincia leads the new trend in the metrology field When metering pump outlet for atmospheric pressure, what measures can be taken to improve the pump repeat measurement accuracy? Installing the valve spring at the metering pump discharge valve improves repeat metering accuracy, but the most effective improvement is the installation of a backpressure valve at the end of the line. How to adjust the back pressure valve? 1. Never exceed the maximum working pressure of the metering pump. 2. When the dosing pump has pressure on the suction side, the pressure on the discharge side of the pump must be at least 1 bar higher than the pressure on the suction side. How to choose the right pulse damper volume? By multiplying the metering capacity (ml) per stroke of the metering pump (ml) by 26, the minimum volume (ml) of the pulsation dampener required to reduce the 90% pulsation can be obtained. How to set the pressure relief valve? The pressure of the safety valve can be adjusted within the range of the rated working pressure of the metering pump. It is not allowed to exceed the maximum working pressure of the metering pump. The safety valve is designed to prevent over-pressurization of the metering pump. For example, if the maximum working pressure of the metering pump is 3 bar, the relief valve pressure should be set at 3 bar, or lower to ensure proper operation of the metering pump. Overpressure is one of the major causes of dosing pump damage. What is the maximum allowable forward pressure when using ProMinent® metering pumps? The Alpha metering pump works properly when the forward pressure is less than 1 bar above the pump discharge pressure. If it exceeds the allowable pressure value, the metering pump can not work normally. If the delivery of liquid is not water, how to calculate the suction height? Divide the metering pump's nominal aspiration height by the specific gravity of the metering liquid. Under what circumstances with self-irrigation suction? Self-priming aspiration can be applied if: 1.Measurement of liquid volatile; 2. Measuring the proportion of liquid larger; 3. When higher stroke frequency is required; 4. Metering pump work in high altitude areas; 5. In the field of application requires a larger tank, and rely on the self-priming pump is not feasible. When running dosing system should pay attention to what important matters? When running dosing system, pay attention to the following points: A. dosing pressure B. Stroke frequency C. Suction height D. Altitude E. Corrosive chemicals More: Provincia leads the new trend in the metrology field When metering pump outlet for atmospheric pressure, what measures can be taken to improve the pump repeat measurement accuracy? Installing the valve spring at the metering pump discharge valve improves repeat metering accuracy, but the most effective improvement is the installation of a backpressure valve at the end of the line. How to adjust the back pressure valve? 1. Never exceed the maximum working pressure of the metering pump. 2. When the dosing pump has pressure on the suction side, the pressure on the discharge side of the pump must be at least 1 bar higher than the pressure on the suction side. How to choose the right pulse damper volume? By multiplying the metering capacity (ml) per stroke of the metering pump (ml) by 26, the minimum volume (ml) of the pulsation dampener required to reduce the 90% pulsation can be obtained. How to set the pressure relief valve? The pressure of the safety valve can be adjusted within the range of the rated working pressure of the metering pump. It is not allowed to exceed the maximum working pressure of the metering pump. The safety valve is designed to prevent over-pressurization of the metering pump. For example, if the maximum working pressure of the metering pump is 3 bar, the relief valve pressure should be set at 3 bar, or lower to ensure proper operation of the metering pump. Overpressure is one of the major causes of dosing pump damage. What is the maximum allowable forward pressure when using ProMinent® metering pumps? The Alpha metering pump works properly when the forward pressure is less than 1 bar above the pump discharge pressure. If it exceeds the allowable pressure value, the metering pump can not work normally. If the delivery of liquid is not water, how to calculate the suction height? Divide the metering pump's nominal aspiration height by the specific gravity of the metering liquid. Under what circumstances with self-irrigation suction? Self-priming aspiration can be applied if: 1.Measurement of liquid volatile; 2. Measuring the proportion of liquid larger; 3. When higher stroke frequency is required; 4. Metering pump work in high altitude areas; 5. In the field of application requires a larger tank, and rely on the self-priming pump is not feasible.
1.MACHINE OVERIEW
Colloid mill is a kind of grinding equipment, integrated homogenizer, ball mill, blender and other mechanical functions, with ultra-micro grinding, emulsification, homogenization, mixing and other effects. After the material processing, the uniformity of more than 90%, particle size up to 2 ~ 50 micron, the parts are made of high quality stainless steel material, corrosion resistance, non-toxic, is the ideal equipment for ultra-fine particle processing
2.MAIN APPLICATION
1. Chemical industry: paints, pigments, dyes, coatings, lubricating oil, diesel oil, catalysts, emulsified asphalt, adhesives, detergents, etc.
2, Food industry: ice cream, moon cake stuffing, cream, jam, juice, soybeans, bean sauce, bean paste, peanut butter, cheese, dairy products, malted milk, all kinds of drinks, etc.
3, Daily chemical industry: toothpaste, detergent, shoe oil, cosmetics, shower gel, soap, balsam, etc.
4, Biopharmaceutical: syrup, nutrition liquid, Chinese patent medicine, cream, cod liver oil, royal jelly, vaccines, oral liquid, static drops, etc.
3.FEATURES
This machine not only maintains the traditional colloid mill reasonable structure, simple operation, convenient maintenance, small volume, light weight characteristics, It also has the characteristics of wide adaptability, simple speed change, and can replace different types of motors for different processing objects.
1, the main parts of the machine are made of stainless steel, corrosion resistant, non-toxic.
2, the main working part of the machine is divided into stator and rotor, excellent processing. The stator and rotor clearance can be micro - sized through the positioning disk adjustment, equipped with dial, easy to control, to ensure product processing quality.
3, according to different uses, can choose different materials of stator and rotor, convenient disassembly.
4, the speed of the machine can be adjusted, the user can order the appropriate speed from our unit according to the material processing situation
In addition we also have other machines for u chosoe,such as spices Powder Pulverizer ,powder mixer,Capsule Filling Machine,capsule Polishing Machine,Capsule Counting Machine,tablet press,vacuum dryer etc
Essence Colloid Mill for Food,Fragrant Emulsified Pig Skin Colloid Mill,Peanut Milk Colloid Mill,Syrup Colloid Mill for Medicine,Proprietary Chinese Medicine. Colloid Mill,Ice Cream Colloid Mill for Food Jiangyin yongchang medicine machinery co,.ltd , https://www.ycgrinderline.com