Submersible pump installation precautions and maintenance

Submersible pump installation precautions Submersible pump is a combination of pump, submersible water work efficient energy-saving water lifting tools. It is small, light weight, compact structure, easy installation and maintenance. With stable performance, continuous operation, reliable, low noise characteristics, and does not pollute the water, environmental protection, pumping efficiency, energy saving, long service life.

1. installation

Submersible pump before installation must first meet the following installation conditions and installation of technical requirements: ① Check the submersible pump is in accordance with the instructions specified in the conditions of use and scope of use. ② Check the well conditions, including well depth, well water, well diameter and the selection of submersible pump to adapt. ③ check wells are clean, well water is turbid, prohibited with submersible pump wash well-pumping water. ④ check the wellhead, the location of the installation of the clamp is appropriate, can withstand the weight of the entire unit. ⑤ check submersible pump parts are complete. ⑥ Check the configuration of the overload protection device and the starting device is compatible with the submersible pump. ⑦ Check the power requirements and the pump nameplate is consistent with the mark.

In the installation process should pay attention to the following:

(1) The phenomenon of stuck during the pump found to rotate or move the water pipe to overcome the stuck point, such as various measures are still not effective, do not force the pump, to avoid the pump and the well stuck or damaged.

(2) When installing each flange on the flange should be put rubber pads and tighten evenly force.

(3) According to the quicksand, silt situation of the well to determine the depth of the pump to the bottom of the well, the pump must not be buried in the mud. Pump to the bottom of the distance is generally not less than 3m.

(4) The depth of the water into the pump should be less than 1 ~ 1.5m away from the water inlet section.

(5) The lift of the pump should not be too low, otherwise, the gate valve should be installed on the wellhead water pipe to control the rated flow point of the pump flow so as to prevent the motor from being overloaded and burned due to the excessive flow.

2. use

After the pump is put into normal operation, in order to prolong the service life, it is necessary to regularly check the power supply voltage, operating current and insulation resistance are normal, such as the following circumstances should be found immediately shut down to check and troubleshooting.

(1) Under rated conditions, the supply voltage is below 10% of normal and the current exceeds 20% of the rated current.

(2) motor thermal insulation resistance of less than 0.5 megaohms (usually a weekly inspection).

(3) All protective devices, electrical meters and starting equipment are abnormal.

(4) water level dropped to the water section, resulting in intermittent water.

(5) Submersible pump violent vibration or noise.

(6) Motor temperature rise exceeds the rated value 45K.

(7) fuse burned one phase.

(8) Sump damage.

3. Maintenance and repair

In order to run normally and extend the life of the pump, under normal circumstances, once every six months or 1500 hours after the operation of a small test to check thrust bearings, thrust plate and guide bearing wear is serious, if severe wear and tear should be promptly replaced, less wear and tear Adjust the adjusting bolt should be appropriate to ensure that the proper amount of axial motor channeling. Check the pump body rotation is uniform, if the phenomenon of stagnation is required to open the pump body Check the rubber bearings, impeller and seal ring wear, such as serious wear and tear should be replaced parts, reassemble and put into use.

After a year or 2500h operation should be carried out a major inspection of all parts for cleaning, descaling, to rust. Check wearing parts wear, severe wear and tear to give replacement.

4. Storage

Submersible pump should be raised when not in use for a long time, and after checking and cleaning, wiping it, then putting it in a dry and ventilated room to save; opening the drain bolt to discharge the water in the motor chamber (winter should be taken care to avoid freezing the motor) Get dressed up. Pumps can not be below 0 ℃ indoors; long-term do not have, the surface of the unit and the pipe to be painted or butter rust, pump storage should be placed.

5. Safety Precautions

(1) electric pump before use, the motor chamber must be filled with water, non-dry running is strictly prohibited.

(2) In strict accordance with the provisions of the head, the flow range of the use of working conditions to prevent the work in the low lift, high flow overload motor burned.

(3) It is forbidden to run the pump under the condition of no water immersion.

(4) When the pump is installed and used, it is forbidden to force the cable, and it is even not allowed to lift the pump from the wellhead with a cable.

(5) motor reversal can not exceed lmin.

(6) Configure safety overload, start the protection device, the protection control performance must meet the product safety control requirements, the capacity must be matched with the pump, non-overload use.

(7) electric pump inspection and maintenance, you must first cut off the power, and then enter the homework.