Sullair screw air compressor installation suggestions

I. The products of Safe Lifeline are carefully designed and manufactured so that they can be safely and reliably operated. However, safe operation still requires the use and maintenance of the machine's staff. The following precautions, if followed carefully, will reduce the accident rate of the machine within the service life. Only trained and authorized personnel can operate the compressor. These people should read the manual carefully and fully understand it. Failure to follow the instructions, work procedures and safety precautions in the manual will result in accidents and even casualties. So be sure to read the operating manual before starting the air compressor. Unless it is safe, it must not be switched on; if it is known that there is a problem, do not start it. At this time, the power should be cut off or the drive must be removed and a mark must be made so that the unsuspecting person will not misoperation. The installation, use and operation of the machine shall strictly comply with the relevant local and local laws and standards. Do not change the device and control method unless written approval from the manufacturer. Note: See Appendix 1 for other safety precautions. Second, the air compressor station design principles 1, air compressor station design should consider the following factors: 1.1 close to the gas load center. 1.2 Power supply and supply are reasonable and convenient. 1.3 There is the possibility of expansion. 1.4 Avoid places that emit harmful substances such as explosive, corrosive and toxic gases and dust, and be located on the windward side of the above-mentioned places as much as possible. 1.5 The distance between the station room and the place where there is noise and vibration protection requirements shall comply with the current relevant regulations. 1.6 There should be enough space outside the air compressor station to ensure hot air discharge of the air compressor. 2. The air compressor station room should have enough space to ensure that the air compressor is no less than 1.5 meters from the top and no less than 2.5 meters from the top. And make sure: Air-cooled machine: 1.35M3/kw space; Water-cooled machine: 0.45M3/kw space. 3, air compressor station house should ensure that there is sufficient natural ventilation, try not to use the auxiliary room design, should use relatively independent station rooms, and try to avoid the West. The design of the air compressor station should take into account the smooth flow of air, the design requirements of the air intake of the engine room and the corresponding air intake of the compressor. The air flow rate of the air inlet should be controlled within 5m/s to avoid negative pressure in the machine room and ensure: Cooler: Ventilation window of 0.015M2/kw; Water cooler: Ventilation window of 0.006M2/kw. And ensure that the air compressor station room temperature does not exceed 40 degrees Celsius. 4, air compressor station room to meet the requirements of the air compressor and its auxiliary equipment installation base. Foundation requirements: The foundation should have enough strength, and the surface of the foundation should be flat and horizontal. The flatness should be controlled within 3mm. Ensure that the bottom of the foundation of the unit is fully grounded. For foundation construction, reference may be made to the size and weight of the hollow compressor in Schedule 1. The foundation size should be slightly larger than the size of the base of the compressor, and it should be more than 10 centimeters around. 5, air compressor station room should be reserved for access, maintenance access, in order to facilitate the entire machine access and maintenance. For a single air-pressure station with a displacement greater than or equal to 20 cubic meters and a total capacity greater than or equal to 60 cubic meters, lifting equipment for overhaul shall be provided. 6, air compressor station house should have necessary antifreeze, warm measures, consider installing heating. 7. The air compressor station should have reasonable drainage, drainage and drainage facilities. 8, air compressor station room to do a good cable pre-embedded, overhead cable routing. 9. Air compressor station houses should be soundproof and noise-reducing measures. If necessary, sound insulation materials can be installed on the walls of station buildings. 10. Compressed air tanks should be located outdoors, and should be located on the north side of the machine room, without affecting the lighting and ventilation. Gas tanks containing less than 1 mg/m3 of oil in compressed air can be placed indoors. Note: The People's Republic of China Standard GB 50029 ━2003 "Design Specification for Compressed Air Stations"

Gasoline Car

As a traditional means of transportation, gasoline vehicles have always played an important role in people's lives. It not only meets people's travel needs, but also has a positive impact on social and economic development.

The history of gasoline cars can be traced back to the late 19th and early 20th centuries. Since Carl Benz invented the first car in the world in 1886, the research, development and production of gasoline vehicles have gradually become the focus of attention. With the continuous development of technology, gasoline vehicles have gradually replaced steam cars and electric vehicles as the mainstream means of transportation. Gasoline vehicles are loved by consumers due to their high speed, long range, and convenient refueling.

Gasoline Car,Used Car,Mpv Car,Trunk Car

Chongqing Huanyu Automobile Sales Company , https://www.cqhuanyuauto.com